BrightLogic OPL
BrightLogic OPL system - four pump laundry unit
BrightLogic is such a flexible system that it’s ideal for small on-premises laundries and large industrial operations alike.
Need one chemical dosed at a higher volume than another? Our mixed pump version will do the job. What about connecting to "intelligent" machines, whilst still being able to operate a manifold system and record pump-cycle information? You can with BrightLogic’s ‘relay mode’. All units are CE and UL approved.
OPL version suitable for a wash load of up to 35kg.
Highflow version suitable for wash load of between 35kg and 100kg.
Hardware features
|
Software features
|
| Formula select, remote programmer |
Technical specifications (OPL)
Voltage/frequency |
100V to 240V AC, 50-60Hz |
Current (@240V) |
L2 - 0.14A, L4 - 0.16A , L6 - 0.16A, L8 - 0.38A, L10 - 0.50A |
Power |
L2 - 36W, L4 - 41W , L6 - 71W, L8 - 102W, L10 - 133W |
Output |
Flush valve - 24V DC, 1.25A (10W) MAX Buzzer/lamp 24V DC, 500mA (10W) MAX |
Signals |
12 - 240V AC or DC |
Flowrate |
6mm (BrightChem) - (maximum @100% 285ml/min) (minimum @ 30% 70ml/min) |
Control circuitry |
16x4 illuminated alphanumeric LCD display. Programming via 9 external keypad keys, security access code. |
Motor |
Brushless - 24V DC, 600mA |
Enclosure |
Glass-filled polypropylene IP44 |
Installation kit |
Available on request |
Approvals |
EMC 89/336/EEC - EN61000-6-2:2005 EN61000-6-4:2007 LVD 72/23/EEC - EN60335-1:2002+A2:2006 |
Dimensions (mm) |
Control box - H266 x W285 x D166 Aditional pumps - H186 x W140 x D166 Logo - H40 x W40 |
Weight (approx.) |
Control box - 2.3 kg Pump module - 1.1 kg |
Flowrates calculated with water and silicone tube BrightChem tube.
Flowrates of other tube materials available on request.
Technical specifications (High-flow)
Voltage/frequency |
100V to 240V AC, 50-60Hz |
Current (@240V) |
L2 - 0.14A, L4 - 0.16A , L6 - 0.16A, L8 - 0.38A, L10 - 0.50A |
Power |
L2 - 36W, L4 - 41W , L6 - 71W, L8 - 102W, L10 - 133W |
Output |
Flush valve - 24V DC, 1.25A (10W) MAX Buzzer/lamp 24V DC, 500mA (10W) MAX |
Signals |
12 - 240V AC or DC |
Flowrate |
10mm (BrightChem) - (maximum @100% 870ml/min) (minimum @ 40% 285ml/min) |
Control circuitry |
16x4 illuminated alphanumeric LCD display. Programming via 9 external keypad keys, security access code. |
Motor |
Brushless - 24V DC, 600mA |
Enclosure |
Glass-filled polypropylene IP45 |
Installation kit |
Available on request |
Approvals |
EMC 89/336/EEC - EN61000-6-2:2005 EN61000-6-4:2007 LVD 72/23/EEC - EN60335-1:2002+A2:2006 |
Dimensions (mm) |
Control box - H266 x W285 x D166 Additional pumps - H186 x W140 x D166 Logo - H40 x W40 |
Weight (approx.) |
Control box - 2.3 kg Pump module - 1.1 kg |
Flowrates calculated with water and silicone tube BrightChem tube.